SIZE | HEIGHT | BIO AREA | TRFR AREA | GROW AREA | RACKS | SHELVING | FOOTPRINT | KWH | PLANTS | PLANTS |
SQM | MM | SQM | SQM | SQM | QTY | QTY | SQM | ELECTRICITY | PER SQM | CAPACITY |
110.00 | 3600 | 3.04 | 5.04 | 96.00 | 4.00 | 2.00 | 128.75 | 51.06 | 9-25 | 864-2400 |
DIMENSIONS | FLOOR | POWER | CYCLE | RACKS | SHELVES | GROW | YIELD(g) | PLANTS | PLANTS |
L x W x H | SQM | kWh / CYCLE | DAYS | UNIT | L x W x H & QTY | SQM | 24 | SQM | PER CYCLE |
10 x 11 x 3.8 | 110 | 34 500 | 52 | 4 | 8 x 1.5 x 2 | 96 | 57 600 | 25 | 2 400 |
ISO BUILDINGS (INTERNAL MEASUREMENT) | LENGTH MM | WIDTH MM | HEIGHT MM | M2 | M3 | FOOTPRINT (EXTERNAL MEASUREMENT) | LENGTH MM | WIDTH MM | THICKNESS MM | M2 |
PRODUCT TRANSFER ROOM | 2 000 | 2 520 | 2 400 | 5.04 | 12.10 | PRODUCT TRANSFER ROOM + BIO ROOM | 2 160 | 4 320 | 80 | 9.33 |
BIO ROOM | 2 000 | 1 520 | 2 400 | 3.04 | 7.30 | VEG & FLOWERING ROOM | 10 320 | 11 320 | 80 | 116.82 |
VEG & FLOWERING ROOM | 10 000 | 11 000 | 3 600 | 110.00 | 396.00 | HVAC SLAB NEEDS (1) | 2 160 | 1 200 | 80 | 2.59 |
TOTAL FOOTPRINT = 128.75 |
TYPE | AREA | SCOPE OF WORK | LENGTH MM | WIDTH MM | THICKNESS MM | SQM |
CONCRETE SLAB | PREP, SUPPLY, PLACE & FINISH CONCRETE SURFACE BED, INCLUDING REINFORCING MESH REF 193, 250 MIC PLASTIC, 30/19 MPA CONCRETE | VEG & FLOWERING BIO SECURE AREA (ISO) + PRODUCT TRANSFER AREA (ISO) HVAC SLAB REQUIREMENTS (1) | 10 320 2 160 2 160 | 11 320 4 320 1 200 | 80 80 80 | 128.75 |
POLYURETHANE | PREP, SUPPLY & INSTALL 4MM STEEL TROWEL, POLYURETHANE (DOVE LIGHT GREY) | VEG & FLOWERING AREA (ISO) BIO SECURE AREA (ISO) + PRODUCT TRANSFER AREA (ISO | 10 320 2 160 | 11 320 4 320 | 4 4 | 126.15 |
EQUIPMENT & SPECIFICATIONS | DAYS | VALUES | QTY | kWh | KW24h | CYCLE |
RADBIO-500-SFX (450 - 550W) PSU RANGE (V) DURATION (HR) VEGETATIVE DURATION (HR) FLOWERING | 21 31 | 450-550W 100V TO 277V 18 12 | 288.00 192.00 | 6 048 5 952 |
||
Average Power (kW ) | 52 | 0.5 | 32 | 16.00 | 9.23 | 12 000 |
RADBIO-300-SFX (250 - 300W) PSU RANGE (V) DURATION (HR) VEGETATIVE DURATION (HR) FLOWERING | 21 31 | 250-300W 100V TO 277V 18 12 | 316.80 211.20 | 6 653 6 547 |
||
Average Power (kW ) | 52 | 0.275 | 64 | 17.60 | 10.15 | 13 200 |
LASER MODULE PLUS 11 RED LASERS, 36VDC, 25 WATTS x 11 LASERS PSU RANGE (V) DURATION (HR) VEGETATIVE DURATION (HR) FLOWERING | 21 31 | 274W 36VDC 6 6 | 52.80 52.80 | 1 109 1 637 |
||
Average Power (kW ) | 52 | 0.275 | 32 | 8.80 | 2.03 | 2 746 |
EARTH SENSE PROBE / SINGLE UNIT, 0.05 mW, 100V-277V PSU RANGE (V) DURATION (HR) VEGETATIVE DURATION (HR) FLOWERING | 21 31 | 100V-277V 100V TO 277V 24 24 | 2.88 2.88 | 60 89 |
||
Average Power (kW ) | 52 | 0.00005 | 2400 | 0.12 | 0.11 | 150 |
HP18DNI / CR06MNI INVERTER HEAT PUMPS PSU RANGE (V) DURATION (HR) VEGETATIVE DURATION (HR) FLOWERING | 21 31 | 100V TO 277V 18 12 | ||||
Average Power (kW ) | 52 | 2.08 | ||||
HVAC SYSTEM HP24CMI / CS70MNI INVERTER HEAT PUMPS PSU RANGE (V) DURATION (HR) VEGETATIVE DURATION (HR) FLOWERING | 21 31 | 277V TO 480V 18 12 | ||||
Average Power (kW ) | 52 | 2.5 | ||||
HVAC SYSTEM HP48CMI / CS120MNI INVERTER HEAT PUMPS PSU RANGE (V) DURATION (HR) VEGETATIVE DURATION (HR) FLOWERING | 21 31 | 277V TO 480V 18 12 | ||||
Average Power (kW ) | 52 | 3.25 | ||||
HVAC SYSTEM HP100HNI / HHS100HPNI PSU RANGE (V) DURATION (HR) VEGETATIVE DURATION (HR) FLOWERING | 21 31 | 277V TO 480V 18 12 | 153.72 102.48 | 3 228 3 177 |
||
Average Power (kW ) | 52 | 8.54 | 1 | 8.54 | 4.93 | 6 405 |
HVAC SYSTEM HP100HNI / HHS100HPNI PSU RANGE (V) DURATION (HR) VEGETATIVE DURATION (HR) FLOWERING | 21 31 | 277V TO 480V 18 12 | ||||
Average Power (kW ) | 52 | 8.54 |