SIZE | HEIGHT | BIO AREA | TRFR AREA | GROW AREA | RACKS | SHELVING | FOOTPRINT | KWH | PLANTS | PLANTS |
SQM | MM | SQM | SQM | SQM | QTY | QTY | SQM | ELECTRICITY | PER SQM | CAPACITY |
36.00 | 3 600 | 2.27 | 3.64 | 24.00 | 2.00 | 2.00 | 49.35 | 13.13 | 9-25 | 216-600 |
DIMENSIONS | FLOOR | POWER | CYCLE | RACKS | SHELVES | GROW | YIELD(g) | PLANTS | PLANTS |
L x W x H | SQM | kWh / CYCLE | DAYS | UNIT | L x W x H & QTY | SQM | 24 | SQM | PER CYCLE |
6 x 6 x 3.8 | 36 | 8 899 | 52 | 2 | 4 x 1.5 x 2 | 24 | 14 400 | 25 | 600 |
ISO BUILDINGS (INTERNAL MEASUREMENT) | LENGTH MM | WIDTH MM | HEIGHT MM | M2 | M3 | FOOTPRINT (EXTERNAL MEASUREMENT) | LENGTH MM | WIDTH MM | THICKNESS MM | M2 |
PRODUCT TRANSFER ROOM | 1 800 | 2 020 | 2 400 | 3.64 | 8.73 | PRODUCT TRANSFER ROOM + BIO ROOM | 1 960 | 3 920 | 80 | 7.68 |
BIO ROOM | 1 800 | 1 520 | 2 400 | 2.74 | 6.57 | VEG & FLOWERING ROOM | 6 220 | 6 320 | 80 | 39.31 |
VEG & FLOWERING ROOM | 6 000 | 6000 | 3 600 | 36.00 | 129.60 | HVAC SLAB NEEDS (1) | 1960 | 1200 | 80 | 2.35 |
TOTAL FOOTPRINT = 49.35 |
TYPE | AREA | SCOPE OF WORK | LENGTH MM | WIDTH MM | THICKNESS MM | SQM |
CONCRETE SLAB | PREP, SUPPLY, PLACE & FINISH CONCRETE SURFACE BED, INCLUDING REINFORCING MESH REF 193, 250 MIC PLASTIC, 30/19 MPA CONCRETE | VEG & FLOWERING BIO SECURE AREA (ISO) + PRODUCT TRANSFER AREA (ISO) HVAC SLAB REQUIREMENTS (1) | 6 220 1 960 1 960 | 6 320 3 920 1 200 | 80 80 80 | 49.35 |
POLYURETHANE | PREP, SUPPLY & INSTALL 4MM STEEL TROWEL, POLYURETHANE (DOVE LIGHT GREY) | VEG & FLOWERING AREA (ISO) BIO SECURE AREA (ISO) + PRODUCT TRANSFER AREA (ISO | 6 220 1 960 | 6 320 3 920 | 4 4 | 46.99 |
EQUIPMENT & SPECIFICATIONS | DAYS | VALUES | QTY | kWh | KW24h | CYCLE |
RADBIO-500-SFX (450 - 550W) PSU RANGE (V) DURATION (HR) VEGETATIVE DURATION (HR) FLOWERING | 21 31 | 450-550W 100V TO 277V 18 12 | 72.00 48.00 | 1 512 1 488 |
||
Average Power (kW ) | 52 | 0.5 | 8 | 4.00 | 2.31 | 3000 |
RADBIO-300-SFX (250 - 300W) PSU RANGE (V) DURATION (HR) VEGETATIVE DURATION (HR) FLOWERING | 21 31 | 250-300W 100V TO 277V 18 12 | 79.20 52.80 | 1 663 1 637 |
||
Average Power (kW ) | 52 | 0.275 | 16 | 4.40 | 2.54 | 3 300 |
LASER MODULE PLUS 11 RED LASERS, 36VDC, 25 WATTS x 11 LASERS PSU RANGE (V) DURATION (HR) VEGETATIVE DURATION (HR) FLOWERING | 21 31 | 274W 36VDC 6 6 | 13.20 13.20 | 277 409 |
||
Average Power (kW ) | 52 | 0.275 | 8 | 2.20 | 0.51 | 686 |
EARTH SENSE PROBE / SINGLE UNIT, 0.05 mW, 100V-277V PSU RANGE (V) DURATION (HR) VEGETATIVE DURATION (HR) FLOWERING | 21 31 | 100V-277V 100V TO 277V 24 24 | 0.72 0.72 | 15 22 |
||
Average Power (kW ) | 52 | 0.00005 | 600 | 0.03 | 0.03 | 37 |
HP18DNI / CR06MNI INVERTER HEAT PUMPS PSU RANGE (V) DURATION (HR) VEGETATIVE DURATION (HR) FLOWERING | 21 31 | 100V TO 277V 18 12 | ||||
Average Power (kW ) | 52 | 2.08 | ||||
HVAC SYSTEM HP24CMI / CS70MNI INVERTER HEAT PUMPS PSU RANGE (V) DURATION (HR) VEGETATIVE DURATION (HR) FLOWERING | 21 31 | 277V TO 480V 18 12 | 45.00 30.00 | 945 930 |
||
Average Power (kW ) | 52 | 2.5 | 1 | 2.50 | 1.44 | 1 875 |
HVAC SYSTEM HP48CMI / CS120MNI INVERTER HEAT PUMPS PSU RANGE (V) DURATION (HR) VEGETATIVE DURATION (HR) FLOWERING | 21 31 | 277V TO 480V 18 12 | ||||
Average Power (kW ) | 52 | 3.25 | ||||
HVAC SYSTEM HP100HNI / HHS100HPNI PSU RANGE (V) DURATION (HR) VEGETATIVE DURATION (HR) FLOWERING | 21 31 | 277V TO 480V 18 12 | ||||
Average Power (kW ) | 52 | 8.54 | ||||
HVAC SYSTEM HP100HNI / HHS100HPNI PSU RANGE (V) DURATION (HR) VEGETATIVE DURATION (HR) FLOWERING | 21 31 | 277V TO 480V 18 12 | ||||
Average Power (kW ) | 52 | 8.54 |